SimuLase
Download Demos
SimuLase
SimuLase_Analyzer
Updates ()
Gain Databases
Introduction
Product
Theoretical Models
How We Do It
How Not To do It
Real Life Examples
Specific Examples
Closed Loop Design
PL Analysis
On-Wafer Testing
Publications


Updates of SimuLase and SimuLase_Analyzer


SimuLase Updates:


09/02/08 Auger module now available. Manual updated to include description of Auger calculations.
SimuLase: New demo version available now with some corrections to the graphics interface.
07/07/08 Release of SimuLase Version 1.1
07/07/08 New tool: New tool calculating the linewidth enhancement factor incorporated.
Export Dataset: New feature that allows to export displayed data into ASCII-files for import into other software like Excel.
SimuLase manual: updated to explain the new features.
Confinement factor: corrected an error in the confinement factor calculation that could have occured if 'Solve Drift Diffusion' was checked or the structure included extremely thin layers.
06/23/08 SimuLase manual: Extended Sec. 5.7, "Possible Speed-Ups", to give some more details for specific examples.
Updated the manual for recent changes in the program.
Created files: SimuLase now also writes out the strain into files named "name_TTT_strain.dat". These files are created in the GainDatabase directory. There is currently no plotting-tool included in SimuLase for these files.
GainDatabase time estimate: Changed the algorithm that estimates the time required to set up a Database.
Drift diffusion solver: corrected an error due to which the drift-diffusion problem was only solved in the calculation for the first entry of the list of carrier densities.
06/19/08 Optical mode solver: Now, the optical confinement factor is no longer calculated from the overlap of the mode with layers marked as being of type 'Well'. Instead, the confinement factor is calculated from the overlap of the mode with all layers where the confinement potential bandgap energy is smaller than the energy corresponding to the operating 'Wavelength' as specified on the 'Advanced' panel of the 'Design Structure' tool.
The type 'Well' or 'Barrier' is now only used for the determination of the required subbands.
Optical mode solver: Increased stability and accuracy such that it should find confined modes where it previously didn't.
Optical mode solver: Corrected error in the confinement factor calculation that appeared for structures with graded composition ('GRINSCH-type' layers).
Plot windows: Corrected error that occured when zooming into plots with log-scale axis.
Current Calculator tool: We added the possibility to calculate for radiative losses averaged for TE- and TM-polarization (Jrad=2/3 Jrad,TE + 1/3 Jrad,TM).
Also, changed the way the material loss or wavelength is re-set after changes in the settings.
Gain vs. Current tool: We added the possibility to calculate for radiative losses averaged for TE- and TM-polarization (Jrad=2/3 Jrad,TE + 1/3 Jrad,TM).
Also, included Auger losses - if available - in the calculation.




SimuLase_Analyzer Updates:

07/07/08 We changed the name of the GUI from GainDatabaseViewerTM to SimuLase_AnalyzerTM, Version 1.1.
All relevant changes made to SimuLase to this date have now been implemented also into SimuLase_Analyzer, including the tools 'Gain vs. Current' and 'Linewidth Enhancement Factor' and the feature 'Export Dataset' that allows to export displayed data.
SimuLase_Analyzer manual: Updated Version of the SimuLase_Analyzer Quick-Start Guide now available.

© 2008 Nonlinear Control Strategies | All Rights Reserved | Design: alturas design